Robot Cable Manufacturer — 12 Published Product-Code Families from 0.14 to 6 mm²

Build the cable around the motion, conductor layout and installation envelope your machine actually uses. Jinyou publishes robot cable and industrial special cable families for fixed and continuous-flex installation conditions; repeated-flex or torsional duty requires construction-specific capability confirmation.

  • Enquiry response within 24 hours
  • 12 published product-code families
  • 0.14-6 mm² published range
  • 1-20 cores plus paired designs

Start with the conductor layout, dimensions, electrical duty and motion envelope. Add a drawing, part number or written specification when available.

Robot Cable Capabilities at a Glance

12 families

YY and RO-F product-code groups published for fixed and moving cable constructions

0.14-6 mm²

Published conductor cross-section envelope across the listed families

1-20 cores

Single-core, multi-core and paired layouts, including constructions up to 8 pairs

24 hours

We respond to enquiries within 24 hours.

5G-20G

Published YY1001 multi-core configuration at 0.5 mm²

2-8 pairs

Published YY1006 paired configuration from 0.14 to 0.3 mm²

Motion Classes to Define Before Robot Cable Selection

A robotic cable is selected by the motion at the installation point, not by the word “flexible” alone. Four motion classes create different stress patterns in conductor strands, insulation, fillers, shields and the outer jacket.

“Cables are often just an afterthought in work cells.” “The most common mistake is the most elementary.” These short practitioner observations point to the same specification gap: cabling is selected after the motion and tooling decisions are already fixed.
  • Fixed Installed, supported and not intended to cycle
  • Flexing Repeated bend around a defined route
  • Continuous flex Guided travel inside a chain or track
  • Torsion Twist around the cable axis during robot motion
Motion Classes Definition Chart

The design priority is a stable conductor arrangement and protection against the installed environment. Give us the core count, cross-section, route, connection function and installation conditions.

Specifications
Published envelope: 1-20 cores, 0.14-6 mm²
Relevant families by construction envelope: YY1001, YY1002, YY1007, YY1008, YY2001 and YY2002

Final family is confirmed against the complete electrical and installation specification.

Bend stress is affected by conductor lay, support, route geometry and jacket behavior. Give us the minimum bend radius, travel, acceleration, cycle rate and the way the cable is anchored.

Specifications
Published envelope: 0.14-6 mm² with single, multi-core and paired layouts
Published dimensional references include: YY1006, YY2006, RO-F5001 and RO-F5005

A family code is a dimensional starting point, not a flex-life claim.

Chain-track duty adds repeated curvature, acceleration and interaction with neighboring cables. Give us the track length, travel, minimum bend radius, speed, acceleration, fill arrangement and cycle rate.

Specifications
Published envelope: includes multi-core and paired constructions
RO-FY5002: combines power-size conductors with a smaller paired element.

Track performance must be specified and verified against the duty figures supplied at quotation.

Torsional motion works the conductor bundle in a different direction from chain travel. Give us the rotation angle, active cable length, rotation rate, combined bend, restraint points and surrounding media.

Specifications
Published catalogue: includes single-core, multi-core, paired and hybrid arrangements, but no torsion rating for these family codes.
RO-FY5006: covers 3-pair and 8-pair dimensional layouts at 0.2 or 0.3 mm².

Construction capability, conductor lay and jacket requirements must be confirmed for the actual motion.

Jacket and Insulation Properties, and Why Moving Cables Fail

A flexible robot cable survives through the interaction of strand layout, conductor support, insulation, fillers and jacket—not through one material label. Research on robot-cable conductors shows that twist pattern and twist pitch can change fatigue behavior, which is why a catalog family cannot substitute for a duty-specific review.

A smaller strand is not always a longer-life answer

Finer conductors can feel more flexible during installation, but motion life still depends on lay pattern, twist pitch, support and the complete construction. The trade-off belongs in the construction review, not in a gauge-only shortcut.

Tensile strength30 MPa
HardnessShore 55
Tear strength135 N/mm²
Tensile modulus280 MPa
Elongation500%
Yield stretch27.6%
Tensile strength25-40 MPa
HardnessShore 75-95
Tear strength35-120 N/mm²
Wear amount45-60 mm²
Elongation400-700%
Published flame propertyUL-94 V0

Five construction elements that change motion behavior

  • Conductor strands

    Strand diameter, grouping and lay influence how local bending strain is shared through the conductor.

  • Insulation

    Insulation must move with the conductor while maintaining electrical separation under repeated mechanical stress.

  • Core arrangement

    Balanced core or pair geometry helps prevent one element from taking a disproportionate share of the motion.

  • Fill and support

    Support elements help the bundle keep its intended geometry as acceleration reverses.

  • Outer jacket

    Jacket selection follows abrasion, media exposure, routing friction and the mechanical protection required.

  • Shield package

    When signal integrity or electromagnetic compatibility matters, specify the shield need and termination method at quotation rather than assuming one universal design.

Cable Jacket and Insulation Properties

Construction Options You Specify at RFQ

The fastest quotation starts with decisions that affect both performance and manufacturability. Tell us what the application requires; we will map those inputs to a published family or a fully custom construction.

  • Core count, pair count and conductor cross-section
  • Power, control, signal or combined function
  • Voltage and current requirements supplied by your design team
  • Fixed, intermittent flex, continuous flex, torsion or combined motion
  • Minimum bend radius, travel and cycle frequency
  • Rotation angle and active length for torsion
  • Chain or track dimensions and fill arrangement
  • Speed, acceleration and anchoring
  • Abrasion points and expected pulling or crushing exposure
  • Required jacket compound or property target
  • Temperature and indoor or outdoor condition
  • Oil, coolant, water, chemicals or ultraviolet exposure
  • Shield requirement and termination method
  • Pairing, impedance or data-transmission requirement
  • Electromagnetic interference environment
  • Color, marking, reel length and packing
  • Prototype, small batch or production quantity
  • Required technical or compliance document scope

Product Code Families: Cores, Cross-Section and Construction

The table below preserves the 12 product-code families and their published dimensional configurations. The risk is treating the nearest American Wire Gauge orientation values as identity conversions. Because Jinyou Cable publishes metric cross-sections from 0.14 to 6 mm², electrical resistance, current capacity and other ratings must be confirmed from the selected construction specification.

Product Code Families Graph
Family Published configuration Cross-section Nearest AWG Published color
YY1001 5G-20G multi-core 0.5 mm² about 20 AWG Gray
YY1002 2-20 cores 0.2-0.3 mm² about 24-22 AWG Gray / black
YY1006 2-8 pairs 0.14-0.3 mm² about 26-22 AWG Green
YY1007 2-core, 3G, 4G and mixed layout 0.3-6 mm² about 22-10 AWG Orange / black
YY1008 3G or 4G 0.5-2.5 mm² about 20-14 AWG Orange / black
YY2001 2-core or 4G-18G 0.5-0.75 mm² about 20-18 AWG Gray
YY2002 4G 0.5-1.5 mm² about 20-16 AWG Gray
YY2006 2-4 pairs 0.2-0.3 mm² about 24-22 AWG Gray
RO-F5001 Single core 0.14-0.75 mm² about 26-18 AWG Multiple colors
RO-F5005 1-4 pairs 0.14-0.75 mm² about 26-18 AWG Multiple colors
RO-FY5002 4 power cores plus 1 smaller pair 0.5-1.5 mm² plus 0.2-0.3 mm² about 20-16 AWG plus 24-22 AWG Black
RO-FY5006 3 or 8 pairs 0.2-0.3 mm² about 24-22 AWG Black

G denotes a construction that includes a green/yellow protective conductor. Electrical resistance, current capacity, voltage, temperature, bend radius and cycle life must be confirmed from the final construction specification rather than inferred from the nearest-AWG column.

Quotation Inputs and Commercial Confirmation

Price follows conductor content, core or pair layout, insulation and jacket requirements, shielding, marking, reel format and order quantity. The written quotation records the offered construction, quantity, commercial terms and schedule for that enquiry.

The short-run trade-off

Small batches reduce inventory exposure, but color, stranding and marking setup is spread across fewer metres. Evaluation samples answer the construction question before a production quantity is released.

Quotation Inputs and Commercial Confirmation
Cost driver Why it matters Practical control
Copper cross-section and length They drive conductor mass and material exposure. Separate fixed and moving sections instead of over-specifying the whole route.
Core, pair and shield layout More elements add stranding, insulation and process steps. Send the real signal and power map so unused elements can be removed.
Jacket and environmental requirements Compound choice and protection targets affect materials and processing. List the actual temperature, media and abrasion conditions.
Color, marking, reel and batch size Changeovers and short runs spread setup across fewer metres. Consolidate compatible lengths and approve one marking specification.

We respond to enquiries within 24 hours. A usable specification with the core or pair count, conductor cross-section, required length and motion duty supports the construction review and quotation.

Order item Information to send Written confirmation
Required quantity Total metres, reel lengths and repeat-order outlook Applicable minimum and batch basis
Evaluation sample Purpose, required length and acceptance method Availability, fee, freight and timing
Production schedule Target delivery date, destination and construction status Lead time and schedule start point
Payment and delivery Destination, trade term and purchasing requirements Payment term and delivery basis
Specification

Published family envelope

The listed product-code families span 0.14 to 6 mm² and include single-core, multi-core, paired and hybrid layouts.

Scale

Quantity

State both the evaluation length and expected production length. The quotation will identify the applicable minimum and reel basis.

Process

Samples and production

Sample availability and the production schedule depend on the confirmed construction and quantity. Their timing and commercial conditions will be stated in writing.

Logistics

Commercial terms

Payment, freight, delivery and document requirements are confirmed in the quotation rather than assumed from a general product page.

Inspection Scope and Order Documentation

Moving-cable quality begins with a controlled specification because a generic “high flex” label does not define the bend, torsion, track or installation stress the construction must withstand. The approved construction, inspection scope and order requirements form the project-specific acceptance reference.

Order-control sequence

  • Specification review

    Record the conductor layout, dimensional family, motion inputs, environment, marking and reel requirement before order release.

  • Construction confirmation

    Put the offered construction and any application-specific limits in the quotation or approved specification.

  • Inspection scope

    Define the required checks, acceptance criteria and evidence before production is released.

  • Document scope

    List every technical, compliance, tender or customs document needed so its availability can be confirmed in writing.

Why motion inputs stay on the purchase record

Repeated-flex claims are meaningful only when the test or acceptance method identifies the motion, radius, active length, load and cycle definition. UL 5770 exists specifically as a recommended practice for evaluating cables in repeated-flexing applications, while published verification records show that results are recorded per cable model and test mode.[3][4]

From RFQ to Finished Reel

Send the input

Share the conductor layout, dimensions and duty, plus a drawing, part number or written specification when available.

Define the duty

State the electrical function, core layout, motion, bend, travel, torsion and environment.

Review the construction

We map the requirement to a published family or define the custom items that need confirmation.

Approve the quotation

Review the offered construction, price, quantity, sample basis, production schedule and payment term in writing.

Confirm the sample

When a sample is required, you approve the construction against your application and acceptance method.

Release production

Production follows the confirmed construction, length, order details and agreed handover scope.

You provide We can determine Why it prevents rework
Core count, pair count and cross-section Dimensional family and conductor layout Prevents an assumed wire map from reaching the sample stage
Fixed, flex, continuous-flex or torsional duty Construction review path Separates fundamentally different mechanical stress cases
Bend radius, travel, speed and acceleration Routing and motion acceptance inputs Connects the cable review to the machine geometry
Rotation angle, active length and cycle rate Torsional duty definition Prevents a bend-only construction from being treated as a robot-wrist solution
Temperature, media, abrasion and outdoor exposure Jacket-property target Prevents a mechanically suitable layout from failing the installation environment
Marking, color, reel length and documents Supply and handover package Keeps receiving, assembly and customs requirements on the same order

Installation details matter after the cable is selected

Industry practitioners repeatedly identify excessive tension, poor anchoring, tight routing, abrasion and ingress as causes of early robotic-cable problems. A sound RFQ therefore includes the installation envelope as well as the conductor specification.

Where These Constructions Are Specified

Jinyou Cable publishes fixed laying, continuous flexing, indoor dry or damp use, and outdoor power or control connection laying as family-level installation conditions. The correct construction still follows the electrical function, movement and environment at the actual installation point.

  • Machine tools

    Moving controls, power feeds and signal paths can require different constructions across the fixed cabinet, track and moving head.

  • Industrial production

    Automation cells often separate static trunk cable from repeated-flex and torsional segments.

  • Office automation

    Repeated movement in compact equipment makes routing space, bend geometry and conductor layout part of the specification.

  • Data-processing equipment

    Power, control and data-transmission needs should be mapped before shield and pair options are chosen.

  • Air-conditioning installation

    Power and control connections may combine fixed routing with movement, moisture or outdoor exposure.

  • Refrigeration equipment

    Temperature, moisture, media and mechanical movement must be stated together when the cable is selected.

When a Continuous-Flex Construction Is the Wrong Choice

More movement capability is not automatically a better specification, and a robot cable is not always the right answer for a linear drag chain. The most flexible cable is not always the best cable for a fixed or purely linear route. Match each route segment to its real stress so cost and mechanical design stay where they add value.

Situation Why it works against you Better route
Long fixed run with only a short moving section Paying for a moving construction along the static route adds cost without changing the duty. Use a fixed control cable for the stationary run and transition to the selected flexible cable at the moving section.
One cable expected to suit track travel and wrist torsion The two motion patterns load the conductor bundle differently and can demand different lay decisions. Separate the chain-track and robot-wrist segments, then transition at a protected connection point.
One-off short length below a practical production batch Color, stranding, marking and line setup are spread over too few metres. Reduce the trial scope and confirm feasibility in the quotation before releasing the approved construction for production volume.

Robot Cable FAQ

What is a robot cable?

A robot cable is an electrical cable whose conductor layout, insulation, support and jacket are selected for a defined robotic motion and environment. The term alone does not specify flex life, bend radius or torsion capacity.

What is the difference between flexible, continuous-flex and torsional cable?

Flexible describes the ability to bend, continuous-flex describes repeated guided travel, and torsional describes repeated twist around the cable axis. These duties use different acceptance inputs, so one label should not be treated as proof of all three.

Is a robot cable the same as an instrumentation cable?

No. Instrumentation cable is defined primarily by process-signal and control requirements, while a robot cable is selected around motion as well as electrical function; a moving instrumentation circuit may need a construction that satisfies both sets of requirements.

What type of wire is used in robotics?

Robotics can use power, servo, control, feedback, data and hybrid cable constructions. The correct wire or multi-conductor cable follows the circuit, motion, routing, electromagnetic environment and connector interface.

How do I compare bending-cycle claims?

Compare only results that state the same motion, bend radius, travel, speed, acceleration, load and end-of-life definition. Published programs such as UL 5770 and model-specific verification records illustrate why a cycle count without a test basis is not a portable rating.

What information is needed for a torsional robot cable quotation?

Send the rotation angle, active cable length, rotation speed, combined bend, restraint points, core or pair layout, conductor cross-section and media environment. We then review the published dimensional family and the required custom construction particulars.

What is the minimum order quantity?

State the evaluation length and expected production length in your enquiry. The applicable minimum, reel basis and any sample conditions will be confirmed in the written quotation.

How long do samples and production take?

Sample and production timing depends on the confirmed construction, quantity and acceptance requirements. The project schedule and its start point will be stated in the written quotation.

Which files can start the quotation?

Include the core or pair count, conductor cross-section, electrical function and motion duty. Add a drawing, part number or written specification when available so the enquiry can be reviewed efficiently.